Typical Application | Product Characteristics | International Compliance |
• Sheathing cable | • Good oil resistance at high temperature • High limited oxygen index value • Low smoke density | • IEC 60502 PVC - ST2 • CAT A |
Property | Test Method | Specification | Unit |
Specific Gravity | ASTM D792 | 1.61 – 1.67 | - |
Hardness ShoreA /10 sec | Hardness ShoreA /10 sec | 91 - 97 | - |
Heat Stability ( at 1800C) | VTPC Method | Min. 300 | Minute |
Volume Resistivity (250C) (x 10E13) | JIS K 6723 | Min. 1 | Ohm.cm |
Tensile Strength | IEC 60811 -1 -1 | Min. 12.5 | MPa |
Elongation at Break | IEC 60811 -1 -1 | Min. 150 | % |
Heat Aging test (100 oC, 168hrs) | |||
Tensile Strength after Aging at 1000C x 168 hrs | IEC 60811 -1 -2 | Min. 12.5 |
MPa |
Elongation at Break after Aging at 1000C x 168 hrs | IEC 60811 -1 -2 | Min. 150 | % |
Retention of Tensile Strength after Aging at 1000C x 168 hrs | IEC 60811 -1 -2 | 75 -125 | % |
Retention of Elongation at Break after Aging at 1000C x 168 hrs | IEC 60811 -1 -2 | 75 -125 | % |
Loss of Mass Aging at 1000C x 168 hrs | IEC 60811 -3-2 | Max. 1.5 | mg/cm2 |
Oil Aging test (70 oC, 4hrs) | |||
Retention of Tensile Strength after aging at 700C x 4 hrs | IEC 60811 -1 -2 | Min. 80 | % |
at 700C x 4 hrs IEC 60811 -1 -2 Min. 80 % Retention of Elongation at Break after Aging at 700C x 4hrs | IEC 60811 -1 -2 | Min. 80 | % |
Limited Oxygen Index | ASTM D 2863 | Min. 40 | % |
HCL Emission: PH (Acid Gas Emission: PH) | IEC 60754-1 |
Min. 2.4 | - |
Smoke Density (Nonflaming mode) | ASTM E662 | Max. 110 | DMC |